NeXus-10 MKII

Versatile and integrated solution

The NeXus-10 is a versatile and integrated system for measuring a wide range of physiological signals simultaneously. It is suitable for measuring a wide range of physiological signals simultaneously. NeXus-10 offers up to 4 channels of brain actitivy or muscle activity as well as up to 4 additional channels for peripheral signals like heart rate, relative blood flow, skin conductance, respiration, temperature, and more. It also has an extra input for triggers and one input for digital sensors.

NeXus-10 by Mind Media for measuring physiology

Features

  • 4 x bipolar ExG | 4 x AUX | 1 x trigger | 1 x digital
  • Sample rates up to 8.192 Hz in 24 bit resolution
  • Active shielding for minimal noise and movement artifacts
  • Bluetooth for wireless data transmission
  • USB for maximum sample rates and data quality
  • LiPo battery pack for 24+ hours recording
  • OLED display for system status
  • SD card memory for ambulant recordings
  • Event trigger interface for synchronization
  • Medical CE certified (I), FDA registered (II)
NeXus-10 equipment wih reliable high quality signals

Reliable high quality signals

NeXus by Mind Media stands for clean signals by using active shielding technology and carbon coated cables for minimal artifacts and noise. We offer shielded sensors for the best signal quality and a minimum of noise. Built with high quality electronics and medical grade technology to perform very reliable and accurate measurements and analysis. This makes NeXus-10 the best device for measuring a wide range of physiological signals simultaneously.

Multimodal data acquisition

NeXus-10 MKII is a multimodal signal acquisition device for measuring a wide variety of physiological signals simultaneously.

  • EEGBrain activity [1-4ch]
  • EEGSlow Cortical Potentials [SCP]
  • EMGMuscle activity [1-4ch]
  • ECGHeart rate
  • ECGBlood Volume Pulse [PPG]
  • RSPRespiration
  • TMPTemperature
  • GSRSkin Conductance [GSR]
NeXus wireless biofeedback and neurofeedback

Wireless data communication

Communicate wirelessly in real-time, using Bluetooth for a great deal of freedom during a session. Link with USB for maximum sample rates or store physiological ambulant data on flash memory.

Easy to use software

The NeXus-10 MKII comes with easy to use BioTrace+ software. It offers a total solution for every application. NeXus-10 and BioTrace+ are a highly customizable platform with a wide range of powerful tools for physiological research and signal processing. Use the NeXus Trigger Interface for event synchronization and registering stimuli.

BioTrace+ Software for biofeedback, neurofeedback and research
  • Software

    BioTrace+ Software

    BioTrace+ is our easy-to-use and fully customizable software for measuring and training physiological data in real-time. It is the ultimate platform for biofeedback, neurofeedback and physiological research. The software comes with every NeXus device.

     

    Learn more »

    BioTrace+ Software
  • Packages

    • BiofeedbackBiofeedback
    • EMG
    • EMG
    • HRV
    • GSR
    • RSP
    • TMP

    Sensors
    2ch ExG
    Bood Volume Pulse
    GSR
    Respiration
    Temperature

    Supplies
    EMG/ECG Electrodes (100x)

    • NeurofeedbackNeurofeedback (4ch)
    • EEG
    • EEG
    • EEG
    • EEG

    Sensors
    4ch EEG LinkedEar

    Supplies
    EEG Electrodes (50x)
    EEG Kit

    • NeurofeedbackNeurofeedback (2ch)
    • EEG
    • EEG

    Sensors
    2ch EEG LinkedEar

    Supplies
    EEG Electrodes (50x)
    EEG Kit

    • NeurofeedbackSCP
    • EEG
    • EOG

    Sensors
    SCP
    2ch ExG

    Supplies
    EEG TP Electrodes (5x)
    EEG TP Kit
    EOG Electrodes (100x)

  • Specifications

    Specifications

    General...
    General
    Resolution24 bit
    Size120 X 140 X 45 mm
    Weight500 grams (incl. battery pack)
    DisplayOLED for system status
    Safety classMedical CE certified (I), FDA registered (II)
    Waranty2 years
    ConnectivityBipolar ExG inputsAUX inputs
    Connectivity
    Channels44
    SignalsElectrophysiological signalsPeripheral signals
    Sample Rate128 - 8.192 Hz128 - 256 Hz
    Input signal difference-100 mV ... +100 mV-2.0 V … +2.0 V
    Common mode range-2.0 V … +2.0 V-1.0 V to +1.0 V
    Gain factor201
    Noise< 1 µV RMS (1 − 64 Hz) < 3 µV RMS (1 to 64 Hz)
    Input impedance> 1 GΩ> 1 GΩ
    CMRR> 90 dB> 80 dB
    Accuracy±2 %±2 %
    ConnectorLEMO 0B series 6 pinLEMO 0B series 5 pin
    Data interface...
    Data interface
    BluetoothUp to 10 meters
    USB2.0
    Data storage4 - 32 GB on SDHC flash card
    Power management...
    Power management
    Power supply8000 mAh LiPo Battery Pack
    Operating time24+ hours
Interested? Get a quote

This website uses cookies to ensure you get the best experience on our website. More information